Customization: | Available |
---|---|
Application: | Solar System Controller |
Rated Voltage: | 24V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SC300 | SC500 | SC700 | SC1000 | |||||
Rated power(W) | 300W | 500W | 700W | 1000W | |||||
Rated DC voltage(V) | 12/24 | ||||||||
Line input |
Input voltage | 165-275V, 90-127V | |||||||
Charge current | 10-30A | ||||||||
Inverter output | Output voltage | 220VAC± 5% | |||||||
Output frequency | 50Hz/60Hz± 1% | ||||||||
Wave form | Pure Sine Wave, THD< 4%(Full Load) | ||||||||
Solar input | Maximum voltage( | 21V or 42V | |||||||
Rated power(w) | 300 | 500 | 700 | 1000 | |||||
Solar Controller | Charge current | 15/30 | 20/30 | 20/40 | 40 | ||||
MPPT range(V) | 12v(12-17) or 24v(24-34) | ||||||||
Charging efficiency | 90%-95%, Peak on 97% | ||||||||
Other |
Over charge protective voltage of battery |
12V(14.3), 24V(28.6) | |||||||
Over charge recover-voltage of battery | 12V(13.7), 24V(27.4) | ||||||||
Voltage drop between solar module and battery |
≤ 0.3V | ||||||||
Voltage drop between loads and battery |
≤ 0.15V | ||||||||
Start speed of cooling fan | Have | ||||||||
Environment Humidity | 0-90% Maximum, non-condensable | ||||||||
Protective Functions | Protection against anti-charge at night; Batteryover charge; over discharge protection; Joint-reversed of solar modules |
||||||||
Control method | MPPT | ||||||||
Size: D*W*H(mm) | 430*145*224 | 380*200*430 | |||||||
N. W& G. W(kg) | 12/15 | 13/16 | 15/18 | 17/20 |
Model | SC1500 | SC2000 | SC3000 | SC5000 | ||||
Rated power(W) | 1500W | 2000W | 3000W | 5000W | ||||
Rated DC voltage(V) | 24Vor48V | 48V or 96V | ||||||
Line input |
Input voltage()V) | 165-275V, 90-127V | ||||||
Charge current | 30-80A | |||||||
Inverter output | Output voltage | 220VAC± 5% | ||||||
Output frequency | 50Hz/60Hz± 1% | |||||||
Wave form | Pure Sine Wave, THD< 4%(Full Load) | |||||||
Solar input | Maximum voltage | 42V or 84V or 168V | ||||||
Rated power()Wp) | 1500 | 2000 | 3000 | 5000 | ||||
Solar controller |
Charge current()A) | 30 | 40 | 40/60 | 60/80A | |||
MPPT range(V) | 24v(24-34)48v(48-68), 96v(96-136) | |||||||
Charging efficiency | 90%-95%, Peak on 97% | |||||||
Others |
Over charge protective voltage of battery |
24V(28.6), 48V(57.2), 96V(114) | ||||||
Over charge recover voltage of battery |
24V(27.4), 48V(54.8), 96V(109.6) | |||||||
Voltage drop between solar module and battery |
≤ 0.5V | |||||||
Voltage drop between loads and battery | ≤ 0.25V | |||||||
Start speed of cooling fan | Have | |||||||
Environment Humidity | 0-90% Maximum, non-condensable | |||||||
Protective Functions | Protection against anti-charge at night; Battery over charge/over discharge protection; Joint-reversed of solar modules | |||||||
Control method | MPPT | |||||||
Size: D*W*H()mm) | 450*230*480 | 450*230*570 | ||||||
N. W& GW()kg) | 26/32 | 32/38 | 40/49 | 49/58 |