Customization: | Available |
---|---|
System: | Off-Grid system |
Certification: | CE, ISO |
Still deciding? Get samples of US$ 1350/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SC1500 | SC2000 | SC3000 | SC5000 | ||||
Rated power(W) | 1500W | 2000W | 3000W | 5000W | ||||
Rated DC voltage(V) | 24Vor48V | 48V or 96V | ||||||
Line input |
Input voltage(V) | 145-280V, 90-127V | ||||||
Charge current(A) | 7-25A | |||||||
Inverter output | Output voltage(V) | 220VAC±5% &5V,12V DC | ||||||
Output frequency | 50Hz/60Hz±1% | |||||||
Wave form | Pure Sine Wave, THD<4%(Full Load) | |||||||
Solar input | Maximum voltage(V) | 42V or 88V or 176V | ||||||
Rated power(Wp) | 1500 | 2000 | 3000 | 5000 | ||||
Solar Controller | Charge current(A) | 50/30 | 40/30 | 60/40 | 80/60 | |||
MPPT range(V) | 24v(20-34)48v(40-68),96v(80-136) | |||||||
Charging efficiency | 90%-95%, Peak on 97% | |||||||
Other |
Over charge protective voltage of battery(V) |
24V(28.6),48V(57.2),96V(114) | ||||||
Over charge recover-voltage of battery(V) | 24V(27.4),48V(54.8),96V(109.6) | |||||||
Voltage drop between solar module and battery(V) |
≤0.5V | |||||||
Voltage drop between loads and battery(V) |
≤0.25V | |||||||
Start speed of cooling fan | Have | |||||||
Environment Humidity | 0-90% Maximum,non-condensable | |||||||
Protective Functions | Protection against anti-charge at night;Battery over charge/over discharge protection; Joint-reversed of solar modules | |||||||
Control method | MPPT | |||||||
Size :D*W*H(mm) | 470*230*480 | 470*230*560 | ||||||
N.W&G.W(kg) | 26/32 | 32/38 | 40/49 | 44/52 |
Model | SC6000 | SC7000 | SC8000 | SC10000 | ||||
Rated power(W) | 6KW | 7KW | 8KW | 10KW | ||||
Rated DC voltage(V) | 96V or 120V | |||||||
Line input |
Input voltage(V) | 145-280V, 90-127V | ||||||
Charge current(A) | 28A-45A | |||||||
Inverter output | Output voltage(V) | 220VAC±5% &5V,12V DC | ||||||
Output frequency | 50Hz/60Hz±1% | |||||||
Wave form | Pure Sine Wave, THD<4%(Full Load) | |||||||
Solar input | Maximum voltage(V) | 176V or 220V | ||||||
Rated power(Wp) | 6kw | 7kw | 8kw | 10kw | ||||
Solar Controller | Charge current(A) | 60A | 80A | 80A | 100A | |||
MPPT range(V) | 96v(80-136);120V(100-170V) | |||||||
Charging efficiency | 90%-95%, Peak on 97% | |||||||
Other |
Over charge protective voltage of battery(V) |
96V(114);120V(142V) | ||||||
Over charge recover-voltage of battery(V) | 96V(109.6);120V(137V) | |||||||
Voltage drop between solar module and battery(V) |
≤0.5V | |||||||
Voltage drop between loads and battery(V) |
≤0.25V | |||||||
Start speed of cooling fan | Have | |||||||
Environment Humidity | 0-90% Maximum,non-condensable | |||||||
Protective Functions | Protection against anti-charge at night;Battery over charge/over discharge protection; Joint-reversed of solar modules | |||||||
Control method | MPPT | |||||||
Size :D*W*H(mm) | 590*470*730 | |||||||
N.W&G.W(kg) | 64/72 | 68/76 | 70/83 | 73/88 |